Head Space Module for H2S ANALYZER Lab or Cubi  

Determination of hydrogen sulphide in solid samples

Head Space Module for H2S ANALYZER
Head Space Module for H2S ANALYZER
 
H2S ANALYZER Cubi (compact version) with Head Space Module
Application: H2S ANALYZER Cubi (compact version) with Head Space Module
 
H2S ANALYZER Lab (laboratory version) with Head Space Module and autosampler
Application: H2S ANALYZER Lab (laboratory version) with Head Space Module and autosampler for liquids

The determination of volatile hydrogen sulphide (H2S) in solid and pasty samples is easily feasible by using a additional manual Head Space Module coupled with the selective H2S ANALYZER of ECH.

Samples are measured by isothermal heating in a closed head space vial. The temperature is adjustable depending on the type of sample. The gas flow within the H2S ANALYZER transfers the volatile H2S into the sensor unit. Even very low H2S concentrations are detectable. No sample preparation is necessary.

As a result of the rapid determination, new opportunities are opened regarding the analysis of H2S. Simple handling of the compact device allows the usage not only for laboratory staff but also for everyone.

  • Features
  • Specifications
  • Application
  • Acessories
  • Consumables
  • Download
  • Ordering

Highlights

H2S from bitumen
Determination of volatile H2S from bitumen using the H2S-Analyzer
 
Different kinds of H2S-containing samples
Different kinds of H2S-containing samples

Head Space Module for H2S Analyzer - Details

  • Gas extracting technique for a fast release and separation of H2S from the sample
  • Sample matrix in closed 20 ml vials - no contact with any parts of the analytical system
  • Temperature control unit for a range between 30 °C and 180 °C
  • Measurement time between 2 min and approx. 15 min, depending on H2S content of the sample
  • Double needle system for gas transfer
  • Bypass switching for continuous gas flow
  • Hand-operated and robust mechanical system

 

 

 

 

 

 

 

 

Advantages

  • Compact and easy to use module
  • Extension of application areas of the H2S ANALYZER
  • Simple coupling with the H2S ANALYZER
  • Extension module for universal determination of H2S in solid, pasty and high viscous samples
  • Even very low H2S concentration detectable
  • Measurement of solid samples without sample preparation
  • Short measurement time
  • Simple handling - usage not only for laboratory staff but also for everyone

 

Technical specifications

Sample type: solid, pasty and high viscous
Sample volume: 0.01 ... 20 mL (g)
Oven temperature range: 30 ... 180 °C
Temperature resolution: 0.1 °C
Heating oven: isothermal
Power supply: 230 V, 50 Hz
Power input: 100 W
 

Applications

By coupling the Head Space Module with the H2S ANALYZER of ECH, different kinds of H2S-containing samples can be analyzed:

  • solid samples, e. g. elementary sulfur, sludge and bitumen
  • liquid samples such as sewage water with sludge
  • pasty samples
  • soil samples and waste

ordering information

 

Dimensions

Dimensions: 13 x 27 x 29 cm (W x H x D)
Weight: 5 kg