MiniLab 33 - On-Site Oil Analyzer           

MiniLab is a comprehensive oil analysis lab

for industrial plants and power plants 

Product Portfolio: MiniLab 33 Comprehensive Oil Analysis System

  • Features
  • Specifications
  • Application
  • Acessories
  • Consumables
  • Download
  • Ordering

Highlights

The MiniLab 33 provides oil condition information including viscosity,chemistry,water and total ferrous wear measurement of normal and abnormal ferrous wear. 


Trivector™ – oil and machine health simplified

The TriVector™ is a simple representation of the integrity of the lubrication system and the health of the machine itself. The Trivector indicates the degree of health in each vector.  In order to understand the Trivector condition, one must measure the key physical and chemical parameters of the oil.
 
The following questions can be answered:

The MiniLab 33 combines three simple tests that take less than 7 minutes to complete

(Click on any three tests images below to watch how-to videos)

TruVu 360 Enterprise Fluid Intelligence

The Minilab 33 uses the TruVu 360 Enterprise Fluid Intelligence software which includes an Asset Management database and a reference oil database which can be expanded by the end user. 

It provides a standard sample trend reports and Diagnostic Sets with alarm limit templates, diagnostics, and recommended actions. It can support automatic email distribution of reports. 

Color-coded Trivector reports provide a clear snapshot of machinery health by identifying parameters that are outside normal limits.
 
 

 

 

Tests: 3 simple tests within minutes to comprehensive oil analysis.

Methodology: ASTM D8120, ASTM D8092, ASTM D7889

Calibration: Factory calibrated, field calibration not required. Validation and standardization fluids supplied.

 

OPERATIONAL SPECIFICATIONS

Environmental Requirements: 5-40°C ambient temperature, 10-80% RH non-condensing, 2000 m maximum altitude

Sample Volume: 30-50 ml, varies with viscosity

Solvents: LaserNet Flush, lamp oil or odorless kerosene.

Target Industries

The MiniLab 33 is ideal for a wide range of industries such as: 

Typical limits for machinery

The most common oil analysis tests and typical alarm limits for several component types are shown below.  Component manufacturers establish alarm limits for their equipment for specified parameters.

 

Accessories & Consumables

Sample Preparation – 1 Simple Step

  1. Homogenize the sample for better water measurement

 

   Homogenizer (on stand) 

 Consumables

 

MiniLab 33 consumables: Cleaning pad, pipette tips, small bottles for water preparation, Ferrocheck vials and boats. 
Spectro Scientific consumables ensure high accuracy and repeatability

 

 

 

ordering information

 

MiniLab 33

35 cm x 50 cm x 53 cm

(13.8” x 19.7” x 21”)

Homogenizer and stand

68 cm x 15 cm x 22 cm

(27” x 6” x 9”)

                             MiniLab 153

                              MiniLab 53

                  FerroCheck 2000 Series

 

                              MiniLab 23